In the wave of Building-Integrated Photovoltaics (BIPV) and roof retrofits, lightweight flexible solar modules are emerging as the go-to solution for structural load challenges. For historic buildings and existing roofs that cannot bear the weight of traditional glass modules, lightweight technology is often the only viable path to a green upgrade.
Our modules feature advanced PEC (Planar Electrical Connection) technology for a flatter, more seamless, and more aesthetically refined electrical connection. Furthermore, they are encapsulated using non-glass, polymer-based lightweight materials. However, behind the sleek aesthetics and lightweight design, developers, architects, and building owners often harbor a major concern: "Can a non-glass, polymer-based flexible panel really withstand a fire?"
In roofing applications, fire safety is not an add-on; it is the compliance lifeline that determines whether a project gets approved.
When evaluating external fire exposure for roofs, the European market relies on EN 13501-5. This standard is based on four test methods defined in CEN/TS 1187 — t1 (Germany), t2 (Nordic countries), t3 (France), and t4 (UK) — each corresponding to different national regulations and fire exposure scenarios. It is important to note that these four methods are parallel and there is no hierarchy among them. "BROOF" is the highest performance class within this classification system (BROOF > CROOF > DROOF > EROOF > FROOF), indicating the best resistance to fire spread and penetration from an external source.
In Germany and other German-speaking markets, t1 is the mainstream requirement, while Nordic markets typically adopt t2. Our products have been tested under both of these methods:
· BROOF (t1) – Adaptability Across All Roof Pitches Based on Test Method 1 of DIN CEN/TS 1187 (burning brand test), the standard test includes two angles: 15° (for intended pitches < 20°) and 45° (for intended pitches ≥ 20°). Under the direct application rules of EN 13501-5, results from the 15° test apply to all roofs ≤ 20°, while results from the 45° test apply to all roofs ≥ 20°. Building on this, the Extended Application standard CEN/TS 16459 (EXAP) can further extend the scope to specific build-ups and parameter variations beyond the tested configuration.
· BROOF (t2) – Surface Spread Control on Specific Build-ups Based on Test Method 2, the test uses a 30° pitch with burning brands under wind velocities of 2 m/s and 4 m/s (three specimens each), assessing fire spread across the roof surface and into the substrate. A t2 rating is highly dependent on the specific roof build-up and substrate (e.g., paired with EPS or other insulation boards), and must correspond exactly to the tested configuration.
To completely eliminate the market's concerns regarding the fire safety of lightweight polymer materials, we didn't take shortcuts. Through continuous R&D iterations, we have achieved a generational leap in fire performance:
· 2nd Generation (2nd Gen.) Lightweight Flexible Modules: Passed the 15° condition of BROOF (t1), providing reliable fire safety protection for low-pitched roofs ≤ 20°.
· 3rd Generation (3rd Gen.) Lightweight Modules: Building on the 2nd Gen, the modules completed the 45° steep-pitch test and passed the baseline tests at MPA, University of Stuttgart (Materialprüfungsanstalt Universität Stuttgart).
Through Extended Application assessment under CEN/TS 16459, they achieved BROOF (t1) certification covering all roof pitches (≤ 20° and all ≥ 20°). In addition, they obtained BROOF (t2) certification at the renowned German fire testing institute, Prüfinstitut Hoch.
This means whether it's a visually sensitive historic metal roof retrofit (like our recent project in Prague, Czechia), complex pitched roofs, or near-vertical steep roofs, the 3rd Gen. modules provide exceptional fire safety protection. One distinction worth noting: for true vertical facade applications, separate evaluation against EN 13501-1 reaction-to-fire classes is required — roof and facade fire safety should not be conflated.
We must emphasize a core principle that is often overlooked: a BROOF rating is granted to the "entire roofing system," not just the PV module alone. Whether for t1 or t2, the validity of the certification is strictly conditional upon the installation conditions and roof build-up.
For example, the t2 classification report issued by PrĂĽfinstitut Hoch is valid only under specific conditions:
Substrate Density: The combustible substrate (e.g., EPS) must have a density no lower than the limit specified in the test report.
Mounting Method: Installation must strictly follow the manufacturer's installation manual.
Any deviation from the substrate, auxiliary materials, or installation methods specified in the test report will void the fire certification and pose severe safety risks.
It should also be noted that EN 13501-5 evaluates roof performance under external fire exposure only; it does not cover internal fires caused by electrical faults within the modules — those fall under EN 13501-1 reaction-to-fire classification and electrical safety measures such as DC arc-fault protection. A complete BIPV safety design must address both dimensions.
Lightweight does not mean compromise. True BIPV innovation is about reducing the building's burden and preserving its aesthetics while raising the safety baseline even higher.
Ready to upgrade your next roofing project?
To learn more about the technical specifications of our PEC-BC modules, contact our sales team via info@peakuppower.com.